| Manufacturer SKU | LMA-1800 |
| Product Type | Detector |
| Compatible System | Conformally coated circuit boards |
| Compliance Standards | DEFLECTOMETER® 7-seg display for sensitivity/frequency/faults and delay/extend; 10 sensitivity levels; 4 frequency levels; advanced loop diagnostics + loop fault memory; call output memory; 2-second delayed detection option; sensitivity boost; Output A presence modes: Infinite Presence or Normal Presence; Output B modes: Presence, Pulse-on-Entry, Pulse-on-Exit, or Fault; fail-safe or fail-secure configurable |
| Installation Features | Power: 10–30 VDC or 14–26 VAC (50 mA max); loop inductance tuning range 20–2500 µH (Q>5); lead-in up to 5,000 ft; lightning/transient protection + transformer-isolated loop input; connector: rear 10-pin Molex type (mates with common 0.156” pitch headers used by many gate/parking/access control devices); pin assignments provided; operating temp -34°C to +74°C |
| Additional Notes | Loop Detector with Deflectometer, 1 channel, 2 output, 10 pin female Molex plug-in, 10 – 30 VDC or 14 – 26 VAC |
| EED SKU | 170950 |