DBL-DSP-22-2 2-CH LOOP DETECTOR

Manufacturer SKU DSP-22-2
Product Type Detector
Material Impact resistant, high temperature plastic enclosure
Functionality Always fail-safe; two independent channels with advanced channel scanning (better noise tolerance; loops can be closer when both on same detector); channel 2 selectable presence or pulse (pulse on entry); 4 sensitivity levels + sensitivity boost per channel; loop monitoring with fault display + fault memory; unique flicker display for channel 2 in pulse mode
Installation & Compatibility Direct replacement for DoorKing Models 9409 & 9405; plugs into DoorKing operator control board loop detector ports; channel 2 supports standard inductive loop or Diablo free exit probe (probe mode pulse-only; not for safety/obstruction); loop inductance 20–1500 µH; 14–27 VDC; outputs: Ch1 solid-state open-drain 250 mA @ 30V max; Ch2 relay (N.O./N.C.) 30 VDC 2A, 110 VDC 0.3A, 125
EED SKU 174364
Application14 - 27 VDC, 2 channel, 2 output, Loop or Free Exit Probe Detector
slide
slide
slide